Description
The standard in sports Medical testing with Pedal Force Measurement
With proven accuracy and reliability, the Excalibur sport is renowned worldwide as “the gold standard in ergometry”. The newly designed and improved Excalibur sport ergometer meets the latest requirements of modern sports medicine and research. Since athletes are becoming more and more powerful and testing more advanced than ever, this ergometer has been developed for extreme workloads up to 2500 watt! The new design ensures maximum stability at these high workloads. Thanks to the increased adjustability, versatile positioning of the test subject has never been better! This Excalibur sport has built-in modified strain gauge technology that measures forces exerted on the pedals during exercise and is supplied with angle detection. Independent measurements of forces in both left and right crank are possible. Wireless transmission of the measured forces to the PC by blue tooth. Note: this setting is supplied with LEM and LEM PFM software (various other modules are available), a computer (we recommend to use this PC only for the LEM software) and an interface cable.
Changing pedals on a regular base
Lode Ergometry Manager – Pedal Force Measurement software module
Advice based on Pedal Force Measurement
Overview
Highlights
Extreme workload range of 8 – 2500 watt
Left and right independent measurements
Special Analysis and Polar Graphs
LEM PFM included
Measurement every 2 degrees
Features
Extreme low start up load
Accurate over a long period of time
Small adjustment steps
Designed to be sweat-proof
Compatible with click pedals
Adjustable handlebar Excalibur Sport
Adjustable saddle Excalibur Sport
Instant maximum load
Compatible with ECG and pulmonary devices
LEM compatible
Specifications
Maximum speed | 40 km/h | 24.9 mph | maximum speed of the treadmill |
Minimum operational speed | 1 km/h | 0.6 mph | minimum speed of the treadmill |
Speed adjustment steps | 0.1 km/h | 0.1 mph | the steps you can adjust the speed with |
Positive elevation | 25 % | maximum positive angle as a percentage | |
Negative elevation | -25 % | maximum negative angle percentage that can be reached |
Workload accuracy below 100 W | 2 W | accuracy of the ergometer below 100 Watt load | |
Workload accuracy from 100 to 1500 W | 2 % | accuracy of the ergometer between 100 and 1500 Watt | |
Workload accuracy over 1500 W | 5 % | accuracy of the ergometer over 1500 Watt |
Allowed user weight | 225 kg | 496 lbs | maximum patient weight |
English user interface | User interface available in English language | ||
Norwegian user interface | User interface available in Norwegian language | ||
Czech user interface | User interface available in Czech language | ||
Danish user interface | User interface available in Danishlanguage | ||
Dutch user interface | User interface available in Dutch language | ||
Finnish user interface | User interface available in Finnish language | ||
French user interface | User interface available in French language | ||
German user interface | User interface available in German language | ||
Italian user interface | User interface available in Italian language | ||
Japanese user interface | User interface available in language | ||
Korean user interface | User interface available in Korean language | ||
Polish user interface | User interface available in Polish language | ||
Portugese user interface | User interface available in Portugese language | ||
Russian user interface | User interface available in Russian language | ||
Spanish user interface | User interface available in Spanish language | ||
Turkish user interface | User interface available in Turkish language | ||
Ukrainian user interface | User interface available in Ukrainian language | ||
Readout Angle | Readout actual elevation on control unit (treadmill only) | ||
Readout Target Angle | Readout the target elevation on control unit (treadmill only) | ||
Readout Distance | Readout the distance on control unit | ||
Readout Speed | readout the actual speed on control unit | ||
Readout Energy | Readout the energy on control unit | ||
Readout Time | Readout time on control unit | ||
Set Display | Choosing parameters to be shown on the display during the stress test | ||
Customized Screenviews | Customized Screenviews | ||
Manual operation mode | Operate manually | ||
Quick start operation mode | Easy quick start possible | ||
Touchscreen | operation by touch screen |
Lode 38K4 interface protocol | Supports communication with Lode 38K4 protocol | ||
Lode ERM interface protocol | supports communication according to the Lode ERM treadmill protocol | ||
"HP Cosmos" interface protocol | supports communication according to the "HP Cosmos" protocol | ||
"Woodway" interface protocol | supports communication according to the "Woodway" protocol | ||
"Trackmaster" interface protocol | supports communication according to the "Trackmaster" protocol | ||
"GE" interface protocol | supports communication according to the "GE" protocol | ||
USB connector | connection via USB possible | ||
RS232 in connector | connection via RS232 |
Screen resolution | 800 x 400 pixels | Screen resolution | |
Walking surface length | 250 cm | 98.4 inch | length of the walking surface |
Walking surface width | 150 cm | 59.1 inch | width of the walking surface |
Step up height | 35 cm | 13.8 inch | height to step up the treadmill |
Product length (cm) | 254 cm | 100 inch | length of product in cm |
Product width (cm) | 246 cm | 96.9 inch | width of the product in cm |
Product height | 130 cm | 51.2 inch | height of product |
Product weight | 850 kg | 1873.9 lbs | the weight of the product |
Power cord 3L+N+PE | permanently installed device | ||
Power cord NEMA | NEMA power cord and connector | ||
Maximum rated power input | 8000 VA | power input | |
3 x 400 V | needed power connection | ||
Maximum motor power | 8 kW | the maximum power the motor will consume |
IEC 60601-1:2005 | the product is IEC 60601-1 3rd edition compliant | ||
ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | ||
ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements |
CE class Im according to MDD93/42/EEC | CE certified | ||
CE class of product with optional SpO2 | IIa | CE class of product with optional SpO2 | |
CE class of product with optional BPM | IIa | CE class of product with optional Blood Pressure Measurement | |
CB according to IECEE CB | CB certified |
Maximum operational temperature | 40 °C | maximum temperature at which the device will work within specification | |
Minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification | |
Maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification | |
Minimum operational air pressure | 70 kPa | minimum airpressure as from which the product will be operating within specification | |
Maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification | |
Minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification | |
Maximum storage & transport temperature | 70 °C | maximum temperature the product may be stored or transported at | |
Minimum storage & transport temperature | -25 °C | minimum temperature the product may be stored and transported at | |
Maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at | |
Minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at | |
Max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at | |
Min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |
Rotational measurement resolution | 2 ° | Resolution in degrees of measurement | |
Pedal Force accuracy | 0.5 N | Measurement accuracy for pedal force |
*Specifications are subject to change without notice.
Accessories
Science
Science
- Analysis of ground reaction force in gait during different phases of pregnancy
- Effect of high-speed treadmill training with a body weight support system in a sport acceleration program with female soccer players
- Increased FXYD1 and PGC‐1α mRNA after blood flow‐restricted running is related to fibre type‐specific AMPK signalling and oxidative stress in human muscle
- The comparison of the field and laboratory walk representative characteristics
- Within-day Energy Deficiency and Metabolic Perturbation in Male Endurance Athletes
Support
The Corival handlebar is adjustable within 0-360 degrees.
During Eccentric or negative ergometry you have to resist against a workload produced by a motor instead of an electromagnet, see article prof. Folgering: Effects of positive and negative exercise on ventilatory CO2 sensitivity.
Yes, you can find interface sheets for most common devices on the website at the "service" tab of this website. If your device is not present you can ask us to support you. In most cases we can quickly provide you with a solution.
The Torque factor is used to calculate braking Torque during Wingate sprinttest. Torque factor x body weight = braking Torque this is used in this test. Lode is using 0.7 as the default Torque factor for normal healthy test subjects. Athletes will need a higher Torque factor to get their optimal braking torque, women slightly lower, testsubjects with severe obesity, muscle atrophy, muscle dystrophy etc will need a lower Torque factor (see lt. Bar Or).
Your Lode ergometer is standard supplied with one display. The contrast of this display is factory set and can adjusted by qualified service personal only. If your ergometer is supplied with a programmable option the contrast of this display can be set as follows: go to SYSTEM PARAMETERS select SETTINGS go to CONTRAST. Change the visability according your wishes and save the changes.
Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.
SPD one sided, It is possible to use one side for normal (sport)shoes and the 'click' side for Shimano shoes.
Service
Part number
925909
Interfacing
Interfacing protocols
Reviews
There are no reviews yet.