Angio imaging – With Stress Support Ultrasound
Modern ergometry setting for Echo Stress Cardiology
Exercise Table for Ultrasound, with electrical adjustable slope (transversal, 45º) for an optimal position of the heart in echo research. Due to a removable part of the back support, a better view of the heart from the back side is possible. The minimum distance to the floor, the adjustable shoulder and hip support together with the adjustability of the Angio imaging ergometer provide an optimal feeling of comfort during exercise for the test subject. The research can be done in a sitting position next to the test subject. The stress support for Ultrasound can be used for other cardiologic exercise research in laying or sitting position as well. It is standard supplied with an easy transport tool to lift the device and move to the desired location.
The Angio imaging is an ergometer that can be used for both arm and supine ergometry. Its compact design makes it universally applicable for ergometric studies in those sectors in which standard ergometry cannot be used. The Angio operates independent of pedaling speed in the range of 7 – 1000 watt. The Angio imaging is standard supplied with a communication module and can therefor be easily controlled by all known stress ECG and pulmonary devices in the world. The workload, rpm and time can be readout from the 7″ colour display. The ergometer is equipped with pedal shoes.
For a 115V setting, please use part numer 967941 when ordering.
Overview
Highlights
Comfortable bed for the Patient
– easy step up
– bedcover roll included
– headrests
– handgrips
High standards
Multifunctional
Reliable and reproducible stress tests
Exercise instead of medicine
Features
Extreme low start up load
Accurate over a long period of time
Small adjustment steps
Compatible with ECG and pulmonary devices
Service friendly ergometer
Versatile Interfacing
No pharmalogical stress needed
Additional features with PCU
– better monitoring because of the additional and larger display
– a perfect combination with BPM
– possibility to measure SpO2
Specifications
Workload range fixed torque | 0,1 - 70 Nm | Workload range in fixed torque mode | |
Minimum load | 7 W | the minimum load the ergometer can provide | |
Maximum peak load | 1000 W | the maximum load the ergometer can provide for a short period of time | |
Minimum load increments | 1 W | the smallest steps with which the load can be added | |
Maximum continuous load | 750 W | the maximum power the ergometer can deliver continuous | |
Hyperbolic workload control | control of workload in hyperbolic way | ||
Linear workload control | control ergometer in a linear way | ||
Fixed torque workload control | control ergometer in a fixed torque way | ||
Maximum rpm independent constant load | 150 rpm | rpm as to which constant load can be applied | |
Minimum rpm independent constant load | 30 rpm | rpm as from which constant load can be applied | |
Optional heart rate controlled workload | control the device optionally through a set heartrate | ||
Electromagnetic "eddy current" braking system | system that very accurately applies a brake to the ergometer | ||
Dynamic calibration | continuous calibration during application of workload |
Workload accuracy from 7 to 100 W | 3 W | accuracy of the ergometer between 7 and 100 Watt | |
Workload accuracy from 100 to 500 W | 3 % | accuracy of the ergometer between 100 and 500 Watt | |
Workload accuracy from 500 to 1000 W | 5 % | accuracy of the ergometer between 500 and 1000 Watt |
Shoe size pedal shoe EU | 32 - 41 | Shoe size belonging to pedal size EU | |
Shoe size pedal shoe US male | 1 - | Shoe size belonging to pedal size US male | |
Shoe size pedal shoe US female | 1 - | Shoe size belonging to pedal size US female | |
Shoe size pedal shoe UK | 12.5 (ch) - 7..5 (ad | Shoe size belonging to pedal size UK | |
Allowed user weight | 160 kg | 352.7 lbs | maximum patient weight |
Pedal shoes | premounted pedal shoes | ||
Adjustability backpanel | 32 ° | degrees from horizontal | |
Adjustability ergometer | 45 ° | degrees from horizontal |
Readout Distance | Readout the distance on control unit | ||
Readout RPM | Readout the actual rpm on control unit | ||
Readout Heartrate | Readout the actual heartarte on control unit | ||
Readout target HR | Readout target heartarte on control unit (only possible with HR option) | ||
Readout Energy | Readout the energy on control unit | ||
Readout Torque | Readout torque on control unit | ||
Readout Time | Readout time on control unit | ||
Readout Power | Readout the actual power on control unit | ||
Set Display | Choosing parameters to be shown on the display during the stress test | ||
Set Resistance | Possibility to define a specific resistance for each test subject | ||
Set P-Slope | Possibility to set the load regulation resistance | ||
Set Mode | Possibility to define parameters to be adjusted during the stress test | ||
Manual operation mode | Operate manually | ||
Preset protocol operation mode | Operate via preset protocols | ||
Terminal operation mode | operate with an external device | ||
External control unit | a control unit is connected with a cable to the ergometer | ||
Selfdesigned protocol operation mode | operate via selfdesigned protocols |
Control Unit with touch screen 7" for ergometer | Can be controlled by the control unit 7" |
Product length (cm) | 212 cm | 83.5 inch | length of product in cm |
Product width (cm) | 52 cm | 20.5 inch | width of the product in cm |
Product height | 118 cm | 46.5 inch | height of product |
Product weight | 140 kg | 308.6 lbs | the weight of the product |
V AC | 230 V | voltage in Volt | |
Phases | 1 | phases | |
Frequency | 50/60 Hz | frequency in Herz | |
Power consumption | 260 W | power consumption in Watt | |
Power cord IEC 60320 C13 with CEE 7/7 plug | European power cord and connector standard supplied with product | ||
Power cord NEMA | NEMA power cord and connector | ||
230 V AC 50/60 Hz (138 VA) | operational power |
IEC 60601-1:2012 | the product is IEC 60601-1 edition 3.1 compliant | ||
ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | ||
ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements |
CE class Im according to MDD93/42/EEC | CE certified | ||
CE class of product with optional SpO2 | IIa | CE class of product with optional SpO2 | |
CE class of product with optional BPM | IIa | CE class of product with optional Blood Pressure Measurement | |
CB according to IECEE CB | CB certified |
Maximum operational temperature | 35 °C | maximum temperature at which the device will work within specification | |
Minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification | |
Maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification | |
Minimum operational air pressure | 80 kPa | minimum airpressure as from which the product will be operating within specification | |
Maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification | |
Minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification | |
Maximum storage & transport temperature | 60 °C | maximum temperature the product may be stored or transported at | |
Minimum storage & transport temperature | -20 °C | minimum temperature the product may be stored and transported at | |
Maximum storage & transport air pressure | 10 kPa | maximum air pressure the product may be stored and transported at | |
Minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at | |
Max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at | |
Min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |
*Specifications are subject to change without notice.
Accessories
Science
Science
- A Doppler Echocardiographic Study of the Myocardial Inotropic Response to Peak Semisupine Exercise in Healthy Children: Development of a Simplified Index of Myocardial Reserve
- A new ultrasonographic technique for diagnosing deep venous insufficiency–imaging and functional evaluation of venous valves by ultrasonography with improved resolution
- Abnormal Coronary Flow Velocity Reserve and Decreased Myocardial Contractile Reserve Are Main Factors in Relation to Physical Exercise Capacity in Cardiac Amyloidosis
- Diagnosis of myocardial viability by exercise echocardiography
- Stress Echocardiographic Evaluation for D-Transposition of the Great Arteries after Atrial Redirection: Unmasking Early Signs of Myocardial Dysfunction and Baffle Stenosis
Support
backsupport: 0-32°; rotation 45°; ergometer range 400 mm
Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode
Not sure what this means? Contact us and we will help you to get the right converter.
You can calculate with the following sizes:
Pedal shoe pediatric:
EU: 24 - 31
US: 8 - 13.5
UK: 6.5 - 12
Pedal shoe (default):
EU: 32 - 41
US male: 1 - 8
US female: 1 - 9
UK: 12.5 (child) - 7.5 (adult)
Pedal shoe XL:
EU: 42 - 48
US male: 8.5 - 13.5
US female: 9.5 - 13
UK: 8 - 13
Service
Part number
967931