Melbourne, Australia
+61 431 324 324
info@medisys.net.au

Angio cpet – with electrical adjustable wall Fixation

Angio cpet – with electrical adjustable wall Fixation

Modern ergometer with multifunctional applications
The wall fastening consists of a vertical rail with hang-up mechanism which makes it possible to move the Angio up and down electrically over a range of 70 cm. Handgrips are standard included in this combination. The Angio is an ergometric unit that can be used for both arm and supine ergometry. Its compact design makes it universally applicable for ergometric studies in those sectors in which standard ergometry cannot be used. The Angio operates independent of pedaling speed in the range of 7 – 1000 watt. The Angio cpet is standard supplied with a communication module and can therefor be easily controlled by all known stress ECG and pulmonary devices in the world. The workload, rpm and time can be readout from the 3,5″ colour display.

SKU: Angio-cpet-with-electrical-adjustable-wall-Fixation Category:

Overview

Highlights

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, ISO and 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Easy to operate

For Lode products this means:
– easy to connect
– easy to move around
– easy user interface

Reliable and reproducible stress tests

The experience of professionals who calibrate many ergometers shows that the Lode ergometers are the most reliable across the complete workload and rpm range and still within specifications even after many years of intensive use.

Additional features with PCU

Besides the possibility to program 24 protocols easily, this control unit offers the following features:
– better monitoring because of the additional and larger display
– a perfect combination with BPM
– possibility to measure SpO2

Features

Accurate over a long period of time

The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.

Extreme low start-up load

The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.

Small adjustment steps

The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.

RS232 connectivity

RS232 ports enable connectivity to most ECG and ergospirometry devices as well as PC’s.

LEM compatible

This product can be used with Lode Ergometry Manager (LEM) software to manage data and to apply specific protocols when a Communication card or Network card is present

LCRM compatible

This product can be used with Lode Cardiac Rehabilitation Manager software (LCRM)

Accessories

Specifications

Specifications

Workload
Workload range fixed torque 0,1 - 70 Nm   Workload range in fixed torque mode
Minimum load 7 W   the minimum load the ergometer can provide
Maximum peak load 1000 W   the maximum load the ergometer can provide for a short period of time
Minimum load increments 1 W   the smallest steps with which the load can be added
Maximum continuous load 750 W   the maximum power the ergometer can deliver continuous
Hyperbolic workload control
 
  control of workload in hyperbolic way
Linear workload control
 
  control ergometer in a linear way
Fixed torque workload control
 
  control ergometer in a fixed torque way
Maximum rpm independent constant load 150 rpm   rpm as to which constant load can be applied
Minimum rpm independent constant load 30 rpm   rpm as from which constant load can be applied
Optional heart rate controlled workload
 
  control the device optionally through a set heartrate
Electromagnetic "eddy current" braking system
 
  system that very accurately applies a brake to the ergometer
Dynamic calibration
 
  continuous calibration during application of workload
Accuracy
Workload accuracy from 7 to 100 W 3 W   accuracy of the ergometer between 7 and 100 Watt
Workload accuracy from 100 to 500 W 3 %   accuracy of the ergometer between 100 and 500 Watt
Workload accuracy from 500 to 1000 W 5 %   accuracy of the ergometer between 500 and 1000 Watt
Comfort
Adjustability range height 700 mm   adjustability range height
User Interface
Readout Distance
 
  Readout the distance on control unit
Readout RPM
 
  Readout the actual rpm on control unit
Readout Heartrate
 
  Readout the actual heartarte on control unit
Readout target HR
 
  Readout target heartarte on control unit (only possible with HR option)
Readout Energy
 
  Readout the energy on control unit
Readout Torque
 
  Readout torque on control unit
Readout Time
 
  Readout time on control unit
Readout Power
 
  Readout the actual power on control unit
Set Display
 
  Choosing parameters to be shown on the display during the stress test
Set Resistance
 
  Possibility to define a specific resistance for each test subject
Set P-Slope
 
  Possibility to set the load regulation resistance
Set Mode
 
  Possibility to define parameters to be adjusted during the stress test
Manual operation mode
 
  Operate manually
Preset protocol operation mode
 
  Operate via preset protocols
Terminal operation mode
 
  operate with an external device
External control unit
 
  a control unit is connected with a cable to the ergometer
Selfdesigned protocol operation mode
 
  operate via selfdesigned protocols
Dimensions
Product length (cm) 68 cm 26.8 inch length of product in cm
Product width (cm) 42 cm 16.5 inch width of the product in cm
Product height 104 cm 40.9 inch height of product
Product weight 55 kg 121.3 lbs the weight of the product
Power Requirements
V AC 100 - 240 V   voltage in Volt
Phases 1   phases
Frequency 50/60 Hz   frequency in Herz
Power consumption 250 W   power consumption in Watt
Power cord IEC 60320 C13 with CEE 7/7 plug
 
  European power cord and connector standard supplied with product
Power cord NEMA
 
  NEMA power cord and connector
Standards & Safety
IEC 60601-1:2012
 
  the product is IEC 60601-1 edition 3.1 compliant
ISO 13485:2016 compliant
 
  Lode fulfils ISO 13485:2016 requirements
ISO 9001:2015 compliant
 
  Lode fulfills ISO 9001: 2015 requirements
Certification
CE class Im according to MDD93/42/EEC
 
  CE certified
CE class of product with optional SpO2 IIa   CE class of product with optional SpO2
CE class of product with optional BPM IIa   CE class of product with optional Blood Pressure Measurement
CB according to IECEE CB - pending
 
  CB certification pending
Environmental Conditions
Maximum operational temperature 35 °C   maximum temperature at which the device will work within specification
Minimum operational temperature 14 °C   minimum temperature at which the device will work within specification
Maximum operational air pressure 106 kPa   maximum air pressure as from which the product will be operating within specification
Minimum operational air pressure 80 kPa   minimum airpressure as from which the product will be operating within specification
Maximum operational non-condensing humidity 90 %   maximum non-condensing humidity at which the product will operate within specification
Minimum operational non-condensing humidity 30 %   minimum non-condensing humidity at which the product will operate within specification
Maximum storage & transport temperature 60 °C   maximum temperature the product may be stored or transported at
Minimum storage & transport temperature -20 °C   minimum temperature the product may be stored and transported at
Maximum storage & transport air pressure 106 kPa   maximum air pressure the product may be stored and transported at
Minimum air pressure storage & transport 50 kPa   minimum air pressure the product may be stored or transported at
Max. humidity storage & transport 95 %   max. non-condensing humidity that the product can be stored or transported at
Min. humidity storage & transport 10 %   minimum non-condensing humidity that the product can be stored or transport at
*Specifications are subject to change without notice.

Science

Science

  • A prognostic scoring system for arm exercise stress testing
  • Arm exercise stress testing: diagnostic options in stable coronary artery disease
  • Arm exercise testing predicts clinical outcome
  • Comparison of Lower- vs. Upper-Body Cooling During Arm Exercise in Hot Conditions
  • Effects of Arm-Cranking Exercise in Cutaneous Microcirculation in Older, Sedentary People
  • Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals (video article)
  • Influence of training status and exercise modality on pulmonary O2 uptake kinetics in pre-pubertal girls
  • Left ventricular mechanical limitations to stroke volume in healthy humans during incremental exercise
  • Physical Fitness of Lower Limb Amputees
  • Studying the cutaneous microcirculatory response during upper-limb exercise in healthy, older, sedentary people
  • Subjective Measures of Exercise Intensity to Gauge Substrate Partitioning in Persons With Paraplegia
  • The effects of arm crank ergometry, cycle ergometry and treadmill walking on postural sway in healthy older females.
  • The influence of crank configuration on muscle activity and torque production during arm crank Ergometry
  • The influence of crank rate on peak oxygen consumption during arm crank ergometry
  • The Influence of Step and Ramp Type Protocols on the Attainment of Peak Physiological Responses During Arm Crank Ergometry
  • The Relation of Arm Exercise Peak Heart Rate to Stress Test Results and Outcome
  • Validity and Reliability of Skill-Related Fitness Tests for Wheelchair-Using Youth With Spina Bifida.

Support

Q - Is it possible to request RPM and Load data through the RS232 port while cycling in Manual mode.

Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.


Q - Can I use a RS232 to USB converter to connect an ergometer?

Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.

Service

Part number
967903

Interfacing

Interfacing protocols

AEI Technologies
BTL
Cardiolex
CareFusion
Carewell
Cognimed
Cortex
Cosmed
Custo Med
Delmar Reynolds
Edan Instruments Inc.
Enverdis GmbH
ET Medical
GE Healthcare
Korr Medical Technologies Inc
Labtech
Med-tronik
Medical Graphics
Medset
Mesa Medizintechnik
Mortara
Neurosoft
Nihon Kohden
Norav
nSpire Health
Parvomedics
Philips Medical
Progetti
Pulse Biomedical, Inc.
Quinton
Schiller
Seiva
Welch Allyn
1350K

 

1500 K / 1550K – Cardiofax V

 

600 USB system

 

9320K

 

AT-10

 

AT-104 PC

 

AT-110

 

AT10 Plus

 

BreezeSuite Software

 

BTL-08 ECG

 

Cardiax PC-EKG

 

Cardio Coach Monitor

 

Cardio Collect 12

 

Cardiologic Explorer 12C Ergo

 

CardioPerfect

 

Cardiosoft

 

Cardiosoft + Corina

 

Cardiosoft MAC 1200 ST

 

CS200

 

Cubestress

 

Custo Diagnostic Stress ECG

 

EC Sense

 

EC12 R/S

 

Edan EC-12 EXPRESS

 

Edan ST-1212 STRESS ECG

 

Ergolog

 

Flashlight

 

GE Case

 

GE Case 8000

 

GE Case Basic

 

GE Case Performance

 

GE Case Premium

 

GE Case Value

 

K5

 

Lactware Software

 

MasterScreen® ECG / Viasys Oxycon Pro

 

Metasoft

 

MOXUS Modular Metabolic System

 

MyStress system

 

PC ECG 1200

 

Poly Spectrum

 

Q-Stress

 

QRS-card

 

Quark CPET

 

Quark PFT

 

Quark RMR

 

StressVue

 

T12

 

TM Cardio 1000/2000

 

TrueOne

 

Vyntus CPX / SentrySuite as from 2.17 software

 

X-scribe

 

Reviews

There are no reviews yet.

Be the first to review “Angio cpet – with electrical adjustable wall Fixation”