Melbourne, Australia
+61 431 324 324
info@medisys.net.au

Angio imaging – With Stress Support Ultrasound

Angio imaging – With Stress Support Ultrasound

Modern ergometry setting for Echo Stress Cardiology
Exercise Table for Ultrasound, with electrical adjustable slope (transversal, 45º) for an optimal position of the heart in echo research. Due to a removable part of the back support, a better view of the heart from the back side is possible. The minimum distance to the floor, the adjustable shoulder and hip support together with the adjustability of the Angio imaging ergometer provide an optimal feeling of comfort during exercise for the test subject. The research can be done in a sitting position next to the test subject. The stress support for Ultrasound can be used for other cardiologic exercise research in laying or sitting position as well. It is standard supplied with an easy transport tool to lift the device and move to the desired location.
The Angio imaging is an ergometer that can be used for both arm and supine ergometry. Its compact design makes it universally applicable for ergometric studies in those sectors in which standard ergometry cannot be used. The Angio operates independent of pedaling speed in the range of 7 – 1000 watt. The Angio imaging is standard supplied with a communication module and can therefor be easily controlled by all known stress ECG and pulmonary devices in the world. The workload, rpm and time can be readout from the 7″ colour display. The ergometer is equipped with pedal shoes.
For a 115V setting, please use part numer 967941 when ordering.

SKU: Imaging-1 Category:

Overview

Highlights

Comfortable bed for the Patient

– soft bed
– easy step up
– bedcover roll included
– headrests
– handgrips

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Multifunctional

The ergometer can be used in various ergometry settings, enabling a multifunctional deployment.

Reliable and reproducible stress tests

The experience of professionals who calibrate many ergometers showed that the Lode ergometers are the most reliable across the complete workload and rpm range and still within specifications even after many years of intensive use.

Exercise instead of medicine

When a test subject is able to do exercise, it is always recommended above pharmacologic stress. It allows objective measurement in either level of cardiac conditioning and/or level of cardiac work. It is safe and perfectly reproducible.

Features

Extreme low start up load

The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.

Accurate over a long period of time

The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.

Small adjustment steps

The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.

Compatible with ECG and pulmonary devices

The Lode ergometers have digital interfaces and can be controlled easily by all known stress ECG and pulmonary devices available in the world. This is one of the reasons why the Lode ergometers are very popular worldwide.

Service friendly ergometer

Lode ergometers are very service friendly. In general, total costs for spare parts are so low that they are negligible. Furthermore, most options are so easy to install and firmware is so easy to update that labor costs are minimal. Moreover, the ergometer can be cleaned easily.

Versatile Interfacing

Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment

No pharmalogical stress needed

No pharmalogical stress needed during Echo Stress Test

Additional features with PCU

Besides the possibility to program 24 protocols easily, this control unit offers the following features:
– better monitoring because of the additional and larger display
– a perfect combination with BPM
– possibility to measure SpO2

Specifications

Workload
Workload range fixed torque 0,1 - 70 Nm Workload range in fixed torque mode
Minimum load 7 W the minimum load the ergometer can provide
Maximum peak load 1000 W the maximum load the ergometer can provide for a short period of time
Minimum load increments 1 W the smallest steps with which the load can be added
Maximum continuous load 750 W the maximum power the ergometer can deliver continuous
Hyperbolic workload control
control of workload in hyperbolic way
Linear workload control
control ergometer in a linear way
Fixed torque workload control
control ergometer in a fixed torque way
Maximum rpm independent constant load 150 rpm rpm as to which constant load can be applied
Minimum rpm independent constant load 30 rpm rpm as from which constant load can be applied
Optional heart rate controlled workload
control the device optionally through a set heartrate
Electromagnetic "eddy current" braking system
system that very accurately applies a brake to the ergometer
Dynamic calibration
continuous calibration during application of workload
Accuracy
Workload accuracy from 7 to 100 W 3 W accuracy of the ergometer between 7 and 100 Watt
Workload accuracy from 100 to 500 W 3 % accuracy of the ergometer between 100 and 500 Watt
Workload accuracy from 500 to 1000 W 5 % accuracy of the ergometer between 500 and 1000 Watt
Comfort
Shoe size pedal shoe EU 32 - 41 Shoe size belonging to pedal size EU
Shoe size pedal shoe US male 1 - Shoe size belonging to pedal size US male
Shoe size pedal shoe US female 1 - Shoe size belonging to pedal size US female
Shoe size pedal shoe UK 12.5 (ch) - 7..5 (ad Shoe size belonging to pedal size UK
Allowed user weight 160 kg 352.7 lbs maximum patient weight
Pedal shoes
premounted pedal shoes
Adjustability backpanel 32 ° degrees from horizontal
Adjustability ergometer 45 ° degrees from horizontal
User Interface
Readout Distance
Readout the distance on control unit
Readout RPM
Readout the actual rpm on control unit
Readout Heartrate
Readout the actual heartarte on control unit
Readout target HR
Readout target heartarte on control unit (only possible with HR option)
Readout Energy
Readout the energy on control unit
Readout Torque
Readout torque on control unit
Readout Time
Readout time on control unit
Readout Power
Readout the actual power on control unit
Set Display
Choosing parameters to be shown on the display during the stress test
Set Resistance
Possibility to define a specific resistance for each test subject
Set P-Slope
Possibility to set the load regulation resistance
Set Mode
Possibility to define parameters to be adjusted during the stress test
Manual operation mode
Operate manually
Preset protocol operation mode
Operate via preset protocols
Terminal operation mode
operate with an external device
External control unit
a control unit is connected with a cable to the ergometer
Selfdesigned protocol operation mode
operate via selfdesigned protocols
Connectivity
Control Unit with touch screen 7" for ergometer
Can be controlled by the control unit 7"
Dimensions
Product length (cm) 212 cm 83.5 inch length of product in cm
Product width (cm) 52 cm 20.5 inch width of the product in cm
Product height 118 cm 46.5 inch height of product
Product weight 140 kg 308.6 lbs the weight of the product
Power Requirements
V AC 230 V voltage in Volt
Phases 1 phases
Frequency 50/60 Hz frequency in Herz
Power consumption 260 W power consumption in Watt
Power cord IEC 60320 C13 with CEE 7/7 plug
European power cord and connector standard supplied with product
Power cord NEMA
NEMA power cord and connector
230 V AC 50/60 Hz (138 VA)
operational power
Standards & Safety
IEC 60601-1:2012
the product is IEC 60601-1 edition 3.1 compliant
ISO 13485:2016 compliant
Lode fulfils ISO 13485:2016 requirements
ISO 9001:2015 compliant
Lode fulfills ISO 9001: 2015 requirements
Certificate
CE class Im according to MDD93/42/EEC
CE certified
CE class of product with optional SpO2 IIa CE class of product with optional SpO2
CE class of product with optional BPM IIa CE class of product with optional Blood Pressure Measurement
CB according to IECEE CB
CB certified
Environmental Conditions
Maximum operational temperature 35 °C maximum temperature at which the device will work within specification
Minimum operational temperature 14 °C minimum temperature at which the device will work within specification
Maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
Minimum operational air pressure 80 kPa minimum airpressure as from which the product will be operating within specification
Maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
Minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
Maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
Minimum storage & transport temperature -20 °C minimum temperature the product may be stored and transported at
Maximum storage & transport air pressure 10 kPa maximum air pressure the product may be stored and transported at
Minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
Max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
*Specifications are subject to change without notice.

Accessories

Science

 

Science

  • A Doppler Echocardiographic Study of the Myocardial Inotropic Response to Peak Semisupine Exercise in Healthy Children: Development of a Simplified Index of Myocardial Reserve
  • A new ultrasonographic technique for diagnosing deep venous insufficiency–imaging and functional evaluation of venous valves by ultrasonography with improved resolution
  • Abnormal Coronary Flow Velocity Reserve and Decreased Myocardial Contractile Reserve Are Main Factors in Relation to Physical Exercise Capacity in Cardiac Amyloidosis
  • Diagnosis of myocardial viability by exercise echocardiography
  • Stress Echocardiographic Evaluation for D-Transposition of the Great Arteries after Atrial Redirection: Unmasking Early Signs of Myocardial Dysfunction and Baffle Stenosis

 

Support

Q - What is the adjustability of the Echo Cardiac Stress Table (ECST)?

backsupport: 0-32°; rotation 45°; ergometer range 400 mm


Q - Is it possible to request RPM and Load data through the RS232 port while cycling in Manual mode.

Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode


Q - Can I use a RS232 to USB converter to connect an ergometer?
Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition. 
Not sure what this means? Contact us and we will help you to get the right converter. 

Q - What are the shoe sizes belonging to the various pedal shoes?

You can calculate with the following sizes:

Pedal shoe pediatric:
EU: 24 - 31
US: 8 - 13.5
UK: 6.5 - 12

Pedal shoe (default):
EU: 32 - 41
US male: 1 - 8
US female: 1 - 9
UK: 12.5 (child) - 7.5 (adult)

Pedal shoe XL:
EU: 42 - 48
US male: 8.5 - 13.5
US female: 9.5 - 13
UK: 8 - 13

Service

Part number
967931

Interfacing

Interfacing protocols

AEI Technologies
AMEDTEC Medizintechnik Aue GmbH
BTL
CareFusion
Cognimed
Cortex
Custo Med
Delmar Reynolds
Edan Instruments Inc.
Enverdis GmbH
ET Medical
GE Healthcare
Korr Medical Technologies Inc
Labtech
Lode
Med-tronik
Medical Graphics
Mesa Medizintechnik
Mortara
Nihon Kohden
Norav
nSpire Health
Parvomedics
Philips Medical
Progetti
Pulse Biomedical, Inc.
Quinton
Schiller
Seiva
Welch Allyn
1350K

 

1500 K / 1550K – Cardiofax V

 

600 USB system

 

9320K

 

AT-10

 

AT-104 PC

 

AT-110

 

AT10 Plus

 

BreezeSuite Software

 

BTL-08 ECG

 

Cardiax PC-EKG

 

Cardio Coach Monitor

 

Cardio Collect 12

 

Cardiologic Explorer 12C Ergo

 

CardioPerfect

 

Cardiosoft

 

Cardiosoft + Corina

 

Cardiosoft MAC 1200 ST

 

CS200

 

Cubestress

 

Custo Diagnostic Stress ECG

 

EC12 R/S

 

ECG Pro

 

Edan EC-12 EXPRESS

 

Edan ST-1212 STRESS ECG

 

Ergolog

 

GE Case

 

GE Case 8000

 

GE Case Basic

 

GE Case Performance

 

GE Case Premium

 

GE Case Value

 

Lactware Software

 

Lode Ergometry Manager

 

MAC 5000

 

MAC 5500st

 

MasterScreen® ECG / Viasys Oxycon Pro

 

Metasoft

 

MOXUS Modular Metabolic System

 

Multi Control

 

MyStress system

 

PC ECG 1200

 

Q-Stress

 

QRS-card

 

StressVue

 

TM Cardio 1000/2000

 

TrueOne

 

X-scribe

 

XR-200

 

Reviews

There are no reviews yet.

Be the first to review “Angio imaging – With Stress Support Ultrasound”

Your email address will not be published.