Corival Recumbent Cpet
Easy positioning and entrance for all test subjects
The latest design of the Corival Recumbent ergometer offers ergometry testing for test subjects up to 300 kg! Easy positioning and access is guaranteed by the electric adjustable seat and adjustable handgrips next to the seat. Moreover, the back support can be adjusted. For safety reasons, the back support can be positioned flat in CPR position in 1 step. This ergometer can be used for elderly and obese people and in rehabilitation settings.
The Corival Recumbent is a special product from our Corival range. The Corival is one of the most popular ergometers worldwide. The low start-up load of 7 Watt is unique. The Corival can be controlled easily by all known stress ECG and pulmonary devices in the world. The ergometer has an eddy current electro-magnetic braking mechanism. The biggest advantage of this system is the accuracy which is one of the most important Lode principles. With this ergometer, the stress tests performed are reliable and reproducible. The workload is adjustable in a range of 7 to 1000 watt. Moreover, the noise level is reduced to a minimum.
Overview
Highlights
Reliable and reproducible stress tests
Maximum patient weight 300 kg
Electric adjustable seat positioning
Adjustable back support with flat CPR position
Suitable for all body postures
Features
Extreme low start up load
Accurate over a long period of time
Small adjustment steps
Compatible with ECG and pulmonary devices
Easy step-through
Specifications
Workload range fixed torque | 0,1 - 70 Nm | Workload range in fixed torque mode | |
Minimum load | 7 W | the minimum load the ergometer can provide | |
Maximum peak load | 1000 W | the maximum load the ergometer can provide for a short period of time | |
Minimum load increments | 1 W | the smallest steps with which the load can be added | |
Maximum continuous load | 750 W | the maximum power the ergometer can deliver continuous | |
Hyperbolic workload control | control of workload in hyperbolic way | ||
Linear workload control | control ergometer in a linear way | ||
Fixed torque workload control | control ergometer in a fixed torque way | ||
Maximum rpm independent constant load | 150 rpm | rpm as to which constant load can be applied | |
Minimum rpm independent constant load | 30 rpm | rpm as from which constant load can be applied | |
Optional heart rate controlled workload | control the device optionally through a set heartrate | ||
Electromagnetic "eddy current" braking system | system that very accurately applies a brake to the ergometer | ||
Dynamic calibration | continuous calibration during application of workload |
Workload accuracy from 7 to 100 W | 3 W | accuracy of the ergometer between 7 and 100 Watt | |
Workload accuracy from 100 to 500 W | 3 % | accuracy of the ergometer between 100 and 500 Watt | |
Workload accuracy from 500 to 1000 W | 5 % | accuracy of the ergometer between 500 and 1000 Watt |
Seat width | 512 mm | 20.2 inch | Width of the seatpillow |
Minimum leg length user (incl. adjustable pedals) | 650 mm | 25.6 inch | leg length to fit to pedals when adjustable cranks are used (measured inseam) |
Allowed user weight | 300 kg | 661.4 lbs | maximum patient weight |
Adjustability range seat | 400 mm | 15.7 inch | seat adjustment range |
Readout Distance | Readout the distance on control unit | ||
Readout RPM | Readout the actual rpm on control unit | ||
Readout Heartrate | Readout the actual heartarte on control unit | ||
Readout target HR | Readout target heartarte on control unit (only possible with HR option) | ||
Readout Energy | Readout the energy on control unit | ||
Readout Torque | Readout torque on control unit | ||
Readout Time | Readout time on control unit | ||
Readout Power | Readout the actual power on control unit | ||
Set Display | Choosing parameters to be shown on the display during the stress test | ||
Set Resistance | Possibility to define a specific resistance for each test subject | ||
Set P-Slope | Possibility to set the load regulation resistance | ||
Set Mode | Possibility to define parameters to be adjusted during the stress test | ||
Manual operation mode | Operate manually | ||
Terminal operation mode | operate with an external device | ||
Selfdesigned protocol operation mode | operate via selfdesigned protocols |
Product length (cm) | 183 cm | 72 inch | length of product in cm |
Product width (cm) | 79 cm | 31.1 inch | width of the product in cm |
Product height | 149 cm | 58.7 inch | height of product |
Product weight | 107 kg | 235.9 lbs | the weight of the product |
V AC | 100 - 240 V | voltage in Volt | |
Phases | 1 | phases | |
Frequency | 50/60 Hz | frequency in Herz | |
Power consumption | 160 W | power consumption in Watt | |
Power cord IEC 60320 C13 with CEE 7/7 plug | European power cord and connector standard supplied with product | ||
Power cord NEMA | NEMA power cord and connector |
IEC 60601-1:2012 |
|
the product is IEC 60601-1 edition 3.1 compliant | |
ISO 13485:2016 compliant |
|
Lode fulfils ISO 13485:2016 requirements | |
ISO 9001:2015 compliant |
|
Lode fulfills ISO 9001: 2015 requirements |
CE class Im according to MDD93/42/EEC
CE certifiedCE class of product with optional SpO2IIaCE class of product with optional SpO2CE class of product with optional BPMIIaCE class of product with optional Blood Pressure MeasurementCB according to IECEE CB - pending
CB certification pending
Maximum operational temperature | 35 °C | maximum temperature at which the device will work within specification | |
Minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification | |
Maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification | |
Minimum operational air pressure | 80 kPa | minimum airpressure as from which the product will be operating within specification | |
Maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification | |
Minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification | |
Maximum storage & transport temperature | 60 °C | maximum temperature the product may be stored or transported at | |
Minimum storage & transport temperature | -20 °C | minimum temperature the product may be stored and transported at | |
Maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at | |
Minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at | |
Max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at | |
Min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |
*Specifications are subject to change without notice.
Accessories
[wcsp_cross_sell orderby=”rand” order=”ASC” product_num=”5″ display_columns=”3″ title=”” product_id=”5812″]
Science
Support
This is possible for all ergometers from 2004 on. Since 2009 it is possible to create yourn own calculation by using the adjustable resistance. Note: both pedalling speed and workload are taken into account by estimating the travelled distance.
The HR option is the well known Polar* heart rate receiver. The receiver is integrated in the software of the controller. The test subject has to wear the heart rate belt around the chest. The receiver is placed in front of the test subject (or integrated in the controller in case of a Corival) and the HR data will be displayed on the controller of the ergometer
Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
The load will only be returned when the pedalling speed is 30 RPM or more. For technical details see the Lode RS232 protocol
Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.
Not sure what this means? Contact us and we will help you to get the right converter.
Service
Part number
969900
Reviews
There are no reviews yet.